 Current Transducer LA 55-P
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
50 A
16019
Electrical data
IPN IPM RM Primary nominal current rms Primary current, measuring range Measuring resistance @ with 12 V with 15 V ISN KN VC IC Vd @ 50 A maxi @ 70 A maxi @ 50 A maxi @ 70 A maxi 50 0 .. 70 TA = 70C TA = 85C RM mini RM maxi RM mini RM maxi 10 10 50 50 100 50 160 90 60 95 60 1) 601) 135 155 135 2) 135 2) A A
Features
* Closed loop (compensated) current
transducer using the Hall effect

* Printed circuit board mounting * Isolated plastic case recognized
according to UL 94-V0.
Secondary nominal current rms Conversion ratio Supply voltage ( 5 %) Current consumption Rms voltage for AC isolation test, 50 Hz, 1 min
50 mA 1 : 1000 12 .. 15 V 10 (@ 15 V) + IS mA 2.5 kV
Advantages
* * * * * * *
Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference * Current overload capability.
Accuracy - Dynamic performance data
X Accuracy @ IPN , TA = 25C
L
@ 15 V ( 5 %) @ 12 .. 15 V ( 5 %)
Linearity error Offset current @ IP = 0, TA = 25C Magnetic offset current 3) @ IP = 0 and specified RM after an overload of 3 x I PN Temperature variation of IO 0C .. + 70C - 25C .. + 85C Reaction time @ 10 % of IPN Response time @ 90 % of IPN Step di/dt accurately followed Frequency bandwidth (- 1 dB)
0.65 0.90 < 0.15 Typ Maxi 0.2 0.3 0.5 0.6
% % % mA mA mA mA ns s A/s kHz
IO IOM IOT tra tr di/dt BW
Applications
* AC variable speed drives and servo
motor drives
0.1 0.1
< 500 <1 > 200 DC .. 200
* Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies
(UPS)
* Switched Mode Power Supplies
(SMPS)
* Power supplies for welding
General data
TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ Mass Standards
1) 2) 3)
applications. - 25 .. + 85 - 40 .. + 90 80 85 18 EN 50178: 1997 C C g
Application Domain
* Industrial.
TA = 70C TA = 85C
Notes:
Measuring range limited to 60 A maxi Measuring range limited to 55 A maxi Result of the coercive field of the magnetic circuit.
page 1/2 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
070103/11
w w w .lem.com
Dimensions LA 55-P
(in mm. 1 mm = 0.0394 inch)
Left view Bottom view
Model + N SP
Connection
Front view Mechanical characteristics
* General tolerance * Primary through-hole * Fastening & connection of secondary
Recommended PCB hole 0.2 mm 12.7 x 7 mm 3 pins 0.63 x 0.56mm 0.9 mm
Safety
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer's operating instructions.
Remarks
* IS is positive when IP flows in the direction of the arrow. * Temperature of the primary conductor should not exceed
90C. * Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole. * In order to achieve the best magnetic coupling, the primary windings have to be wound over the top edge of the device. * This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us.
070103/11
Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected.
page 2/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com


▲Up To Search▲   

 
Price & Availability of LA55-P07

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X